6. Installation Examples
Figure 11
Twin Motor Installation Example
Where two motors are to be used, follow the below methods for each motor then join into the “Y” piece prior to
joining ducting to the canopy / rangehood. Refer gure 11.
The two motors can be wired by one of the following methods:
• Wired into one plug by an electrician
• A double adaptor plugged into the lead from the canopy / rangehood
Flue cover
Try to keep length of
exible ducting as even
as possible other wise
motors will draw air o
each other
Roof mount option Roof mount option
Ensure exible ducting is
fully extended and as short
as possible. Use smooth
owing curves for maximum
air ow. Remove excess
ducting by trimming to
length. Always keep ducting
taut.
Flexi ducting 200mm
‘Y’ Junction for Twin 650 Motor