Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/14534647-pkds3131-r2s1/bgb.png)
Page 11
Eaves Installation
After ensuring sucient clearance exists for the mounting ange and ducting, refer gure 1, cut a circular hole
165mm Ø, maintaining adequate clearances. The eaves sheeting should be reinforced.
Pre-drill mounting ange recess. Refer gure 3.
If access to the eaves space is restricted, before xing mounting ange to eaves, preassemble mounting ange,
PVC pipe, bell-mouth adaptor and exi-duct then feed up into roof space. Remember to run power cord through
the assembly and out the slotted PVC pipe wall, refer gure 3.
Fit fan module to mounting ange by placing in position, rotating clockwise to engage bayonet ngers then
secure by screwing in locking screw (while holding fan module rmly in the fully clockwise position).
Ensure that one of the three
bayonet ngers is accessible
for securing locking screw
Bell-mouth Adaptor
Roof Cladding
Locking Screw
Pre-drill mounting
ange recess and secure
to reinforced eaves
sheet using #8 self
tapping screws
Wall
Eaves
Top Plate
150mm Ducting
Roof Frame/Truss
Figure 3
IMPORANT
For more exible ducting instructions, refer page 19.
NOTE: Ensure that power cord is
feed through exit slot and is not
allowed to double back restricting
fan inlet.
4. Installation
Loading ...
Loading ...