6 Cyclone Canopy Installation - English
MOUNTING HEIGHTS AND CLEARANCE
e hood should be installed at 28” minimum above the
cooking surface. If pairing your range hood with a gas
stove minimum mounting height must be 30” above the
cooking surface.
WARNING
Minimum mount height between range top to hood bottom should
be no less than 28” for electric or ceramic stoves, and no less than 30”
for gas stoves. e maximum mount height should be no more than
36”. e hood must be installed at the correct mounting height. Hoods
mounted too low could result in heat damage. Hoods mounted too
high, on the other hand, will be less eective and performance may
suer.
Check your ceiling height and the hood height maximum before
you select your hood.
Hood installation height above cook top is the user’s preference.
e lower the hood is above the cook top the more ecient it will
be in drawing out cooking odors, grease and smoke.
WIRING INSTALLATION
Grounding Instructions
is appliance must be grounded.
is appliance is equipped with a cord having a grounding wire or
with a plug having grounding wire. e grounding wire must be
grounded properly in the junction box or the plug must be plugged
into an outlet that is properly installed and grounded.
1. Connect the power line ground wire to the green ground wire
supplied with the hood.
2. Connect the black power wire to the black wire supplied with
the hood.
3. Connect the white neutral wire to the white wire supplied with
the hood.
Max. 36”
Exactly 2 ¾”
Install the Electrical Power Supply
Position the outlet or junction box within the space covered by
the chimney ue. Place the outlet or junction box at a maximum
distance of 36” above from where the cord exits from the hood.
e center of the outlet or junction box should be positioned at 2
¾” away from the center of the damper. Make sure this does not
interfere with the mounting area, ducting or chimney ue.
Min:
Ceramic/Electric
28”
Gas
30”
Max:
36”
36”
Green: Ground
White: Neutral
Black: Power
is appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected
by a circuit breaker or time delay fuse.