INSTALLATION - ELECTRICAL CONNECTION
This installation must be undertaken by a licensed and authorised
technician.
The electrical supply for the oven must be a 240 Volt 50 Hz.
The fuse and electrical wiring of the dwelling must support the
load of the oven.
The oven must be earthed. Connect the oven to a properly
earthed and rated power socket, as appropriate.
The flexible cord of the oven must not be subject to direct heat
and must be positioned after installation so that its temperature
does not exceed 75°C.
IMPORTANT: If a power socket needs to be installed or relocated, the
work must be done by a licensed electrician.
IMPORTANT: For models supplied without a plug a means for
disconnection shall be incorporated in the fixed wiring according to the
wiring rules of the local electrical authorities.
In New Zealand the oven must be connected to the supply by a supply
cord fitted with an appropriately rated plug that is compatible with the
socket-outlet fitted to the final sub-circuit in the fixed wiring that is
intended to supply the oven.
After installation, perform a brief test of the oven following the instructions
in this manual. In the event that the oven does not function, disconnect it
from the electricity supply and contact your nearest technical service
centre.
The oven is powered by a cable:
- yellow green= earth
- blue = neutral
- brown = phase
The manufacturer does not accept any responsibility for damages to
persons or objects caused by a failure to observe the above prescriptions
or due to tampering with even one single part of the device or the use of
non-original spare parts.