of Dangerous Goods; and Commission, as applicable; and shall be provided with a listed overfilling
prevention device.
- Read labels on the L.P. Gas Supply Cylinder.
- New cylinders are always shipped empty for safety.
- Allow only qualified L.P. gas dealers to fill or repair your L.P. gas supply cylinder.
- Inform the gas dealer if it is a new or used cylinder to be filled.
- After filling, have the gas dealer check for leaks and to see that the relief valve remains free to
function.
Hose and Regulator (Comes standard with the grill)
The Type 1 connection system has the following features:
- The system will not allow gas to flow until a positive connection
has been made.
NOTE: The cylinder control valve must be turned off before
any connection is made or removed.
- The system has a thermal element that will shut off the flow of gas
in the event of a fire.
- The system has a flow limiting device which, when activated, will
limit the flow of gas to 10 cubic feet per hour.
- NEVER use grill without leak testing this connection.
LP (Propane) Gas Supply Connection
1. The tank valve should be in the “OFF” position. If not, turn the knob
clockwise until it stops.
2. Make sure all burner valves are in the “OFF” position.
3. Always connect the gas supply regulator as follows:
Insert the regulator inlet into the tank valve and turn the coupling nut
clockwise until the coupler tightens up (see picture). Do not over
tighten the coupler. Turn the main tank valve on and turn the burner
control valves on the unit to the “HIGH” position for about 20 seconds
to allow the air in the system to purge before attempting to light the burners.
Pre-Operation Leak Testing
DANGER
1. Do not insert any tool into the valve outlet or safety relief valve. You may damage the valve and
cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
2. If a leak is detected at any time or you cannot stop a gas leak, immediately close pipeline valve
and call LP gas supplier or you fire department!
3. Check all gas supply fittings before each use and each time the gas supply cylinder is connected
to the regulator. Have a qualified service technician leak test the grill any time a part of the gas
system is replaced.