CLEARANCES
Installation clearances and protection of combustible surfaces shall comply with the current
local regulations eg. AS/NZS5601.1 (latest edition) Gas Installations code.
Installation shall comply with the dimension in g. 1a bearing in mind that.
Overhead Clearances
In no case shall the clearances between the highest part of the cooker be less than 650
mm or for an overhead exhaust fan 750 mm. AII other downward facing combustible
surfaces less than 650 mm above the cooker surface shall be protected for the full width
of the cooking surface in accordance with the standards noted above. In no case shall the
clearance be less than 450 mm.
MAXIMUM HEIGHT OF THE TOP OF THE PAN SUPPORTS WITH RESPECT TO THE
SURFACE THAT SUPPORTS THE APPLIANCE: 914÷965 mm ±3 (depending on feet
regulation, from feet completely screwed to feet adjusted in height).
Rear and Side Clearances
Where the dimensions from the periphery of the nearest burner to any vertical combustible
surface is less than 200 mm the surface shall be protected in accordance with the standards
to a height of not less than 150 mm above the cooking surface for the full width or depth of
the cooking surface.
Where the dimensions from the periphery of the nearest burner to any horizontal combustible
surface is less than 200 mm, the horizontal surface shall be greater than 10 mm below the
surface of the hob, or the horizontal surface requirement above.
Protection of combustible surfaces
The standards above specify that where required protection shall ensure that the surface
temperature of the combustible surface does not exceed 65 °C above room temperature.
Do not install the cooker near ammable materials (eg curtains).
If the cooker is located on a pedestal it is necessary to provide safety measures to
prevent falling out.
Figure 1
200 mm
750 mm
500 mm
450 mm
Cooker overall dimensions [mm]
height: min 897.5 - max 939
width: 897
depth: 600