LOCATING THE GRILL
This gas appliance is designed and certified for outdoor use only. Do not locate this grill under overhead
unprotected combustible surfaces. When installed under overhead combustible surfaces, a certified ventilating
hood wider than the appliance shall be installed with a minimum distance of 36 inches above the cooking
surface.
CAUTION should be taken when grills are used near glass, vinyl siding or other temperature sensitive
construction materials. In some cases it may be necessary to increase the clearance around the grill to avoid
damage to vinyl siding. Check with the manufacturer of the siding material for details
Do not operate the grill inside a building, garage, recreation vehicle or any enclosed area. When
choosing an area, consider exposure to wind, proximity to traffic paths and length of gas supply line. Keep
gas supply lines as short as possible to reduce pressure drop. Keep the grill away from windy area but keep
the grill in a well-ventilated area. Do not obstruct the flow of combustion and ventilation air around the grill.
The supporting edges of the grill must be located level and flat. The counter should also be leveled.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of 12” from the sides and 12” from the back of the grill to adjacent vertical
combustible construction must be maintained. (Note: To minimize the possibility of discoloration on
adjacent construction extending above the counter-top surface due to grease and hot vapors, it is highly
recommended that a clearance of 18 inches be maintained from sides and back of the grill.)
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE
Il faut maintenir une distance minimum de 12 po (30.48 cm) sur les côtés et de 12 po (30.48 cm) sur
l’arrière du gril par rapport aux constructions combustibles verticales adjacentes. (Note: Pour minimiser la
possibilité de décoloration sur la construction adjacente s’étendant au-dessus de la surface du comptoir en
raison de la graisse et des vapeurs chaudes, il est fortement recommandé de maintenir un dégagement de 18 po
(45.72 cm). sur les côtés et l’arrière du gril.)
CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION
A minimum clearance of 2 ½” from the back of the grill above cooking surface to non-combustible
construction is required to allow the grill hood to open completely.
A minimum of 6” clearance to the sides of the grill above cooking surface to non-combustible construction
is recommended. The grill can be installed directly next to non-combustible construction below the cooking
surface.
DÉGAGEMENT DE TOUTE CONSTRUCTION INCOMBUSTIBLE
Une distance minimum de 2 ½ po (6.25 cm) de l’arrière du gril au-dessus de toute surface de cuisson à la
construction incombustible est prescrite pour permettre à la hotte d’ouvrir complètement. Une distance
minimum de 6 po (15.24 cm) des côtés du gril au-dessus de la surface de cuisson à la construction
incombustible est recommandée pour prévoir de l’espace pour le moteur de la rôtissoire et la poignée des
broches de cuisson. Le gril peut être installé directement à proximité d’une construction incombustible en-
dessous de la surface de cuisson.