Installation instructions
TR4000 | TR4000R – 6 720 876 021 (2017/11)
12
Important: Connect the unit only to a mains socket with
protective contact that is installed according to regulations.
Do not use an extension cord. If necessary, equip the unit
with a longer cord.
2.5 Only for TR4000 5 ET, TR4000 6 ET, TR4000 6
EB, TR4000 8 ET and TR4000 8 EB (fixed
electrical connection)
Press the upper and lower latches (C1), then remove
the housing cover (C2).
FIG. 3 . Wall mounting
2.6 Undersink appliances
Attach mounting template D to the wall.
Mark the locations for the holes; drill the holes and insert
the wall plugs.
Attach the installation bracket to the wall using the
screws (D1).
Only for permanently installed appliances:
Pass the connection cable through the cable grommet,
suspend the appliance in the installation bracket and screw
it onto the mounting bracket (D2).
Only for appliances with mains plug:
Suspend the appliance in the installation bracket and screw
it onto the mounting bracket (D3).
2.7 Over-sink appliances
Attach mounting template E to the wall.
Mark the locations for the holes; drill the holes and insert
the wall plugs.
Attach the installation bracket to the wall (E1).
Pass the connection cable through the cable grommet,
suspend the appliance in the installation bracket and screw
it onto the mounting bracket (E2).
2.8 Only for TR4000 5 ET, TR4000 6 ET, TR4000 6
EB, TR4000 8 ET and TR4000 8 EB (fixed
electrical connection)
The variants for feed through of cables using flush mounting
electrical connection should be observed on the mounting
template.
The cable grommet must completely enclose the connection
cable to guarantee optimum protection against dampness.
The opening must be sealed watertight if it is damaged.
Use the openings provided on the rear for mounting.
Water connection (Fig. 4)
Left: pressurised (closed);
right: unpressurised (open)
The appliance is only approved for heating water with
a specific electric resistance of ≥ 1 300 Ωcm at 15 °C.
Your water utility company can give you information about
the specific water resistance.
2.9 Installation
Ensure the axial fit of the connection pipes in the nozzles.
Tighten the union nuts on the nozzles with an open-end
wrench and counter hold with a suitable open-end wrench.
The T-piece (for the pressurised connection) and flexible
connection hose are available commercially.
Only the approved unpressurised valves may be used when
connecting without pressure (Special accessories: Single-
lever mixer tap BZ13062, Two handle fixture BZ13051).
Exchange the perlator from the tap fixture with the supplied
aerator to change the spray pattern of the tap.
2.10 Controlling temperature
The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap.
Turn the valve slowly in the closed direction for higher
temperatures (F1).
Add cold water for lower temperatures (F2).
Electrical connection (Fig. 5)
2.11 TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,
TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
Connect the appliance on the terminal strip in accordance
with the connection schematic.
Put on the housing cover and push it onto the rear wall of
the appliance so that the upper and lower latches engage.
2.12 TR4000 4 ET and TR4000R 4 ET
Replacing the Power Supply Cord:
The power supply cord must be replaced by our customer
service only in order to avoid a hazard. The mains plug must
be pulled before replacing.