Clearances
Rangehoods and overhead exhaust fans must be installed according to the manufacturers’ instructions
and local regulations but in no case shall clearance from hob burners be less than 600mm for the
rangehood and 750mm for the overhead exhaust fan.
At all times gas safety regulations and local building codes must be adhered to.
Removing Legs and placing oven on a plinth
If the legs are removed and the oven is placed on a plinth, then suitable ventilation from the plinth area is
required. It is recommended that an air vent 20 mm wide and a length of 100mm less than the width of
the oven it is be located at the rear in the base of the plinth. If the area under the plinth is sealed it is also
recommended that an additional vent be included at the top of kick panel under the plinth to provide
adequate circulation. The vent size should be 10mm high and 100mm less than the width of the oven.