GAS INJECTOR SELECTION TABLE
COOKTOP
BURNER TYPE
NATURAL GAS ULPG
Inj. Diam. MJ/h Gas Press. Inj. Diam. MJ/h Gas Press.
Wok Burner 1.80 14.4 1.0 1.00
13.0
2.75
Large/Fish Burner 1.55 11.5 1.0 0.88 10.0 2.75
Meduim Burner 1.18 7.0 1.0 0.68 6.0 2.75
Small Burner 0.90 4.0 1.0 0.52 3.5 2.75
OVEN BURNERS
53/60/70cm 1.41 9.0 1.0 0.79 8.5 2.75
80cm 1.75 14.5 1.0 0.96 12.5 2.75
90cm 1.85 15.5 1.0 1.00 13.0 2.75
FINAL CHECK
Operate all cooker burners on high and low flames and check that each burner ignites properly
and has a stable flame. The following may be considered to be abnormal:
If the burners have yellow tipping.
If the pots are sooting up underneath.
If the burners are extinguished by opening and closing the oven door.
If the burners fail to ignite properly.
If the burners fail to remain alight.
If the electrodes constantly click when burners are alight.
When satisfied with the operation of the cooker, please explain to the user the correct method of
operation. If the cooker fails to operate correctly, contact your local service agent.
Gas checks and adjustments -igniter operation
Check that the igniter for each burner successfully ignites the gas and that the burner remains
alight. If an igniter fails to work or a burner fails to remain alight, first remove the plug from the
electrical power outlet, and then check that all the electrical connections are in place. If the
cooker fails to operate correctly, call Glem Gas or their appointed agent for service.
Do not attempt repairs yourself.
Gas checks and adjustments -pressure adjustment
First shut off the gas to the appliance. Remove the sealing screw from the regulator test point at
the rear of the cooker and attach the hose from the manometer to the point. Turn the gas back
and light the largest burner and smallest burner at the maximum setting. Check the pressure and
adjust at the regulator if necessary to the settings in the table or on the data plate. For propane
gas adjust at the regulator at the cylinder. Turn regulator adjusting screw clockwise to increase
pressure and anti clockwise to reduce pressure. Refit the test point sealing screw when finished.
NOTE!
THIS COOKER MUST BE INSTALLED BY A LICENSED GAS FITTER. WRITTEN PROOF IS
REQUIRED FOR WARRANTY SERVICE. STANDARD PLUMBERS TEFLON TAPE SHOULD
NOT BE USED TO SEAL JOINTS. AN APPROPRIATE GAS SEALING TAPE MUST BE USED.
IF IN DOUBT ON ANY INSTALLATION POINTS PLEASE CALL 1300 307 917 FOR MORE
INFORMATION.