DIMENSION DETAILS
1. Location of gas inlet
Bottom rear of upright cooker:
60 mm from right hand side
400 mm from the bottom of the cooker plus the height of the legs.
2. Electrical connection
Connection is by means of flexible cord and plug. Check the data plate - models with electrical
consumption greater than 2400W will require a 15 amp connection.
3. Overall dimensions of cooker
Depth over cabinet 600 mm - all models
Height over cooktop is either 760 mm or 750 mm (check model)
Height over splashback is either 810 mm or 820 mm (check model)
4. Width of cooker models:
534 series width 530 mm
664 series width 598 mm
765 series width 698 mm
865 series width 798 mm
965 series width 898 mm
Height of legs must be added to overall cooker dimensions
Height adjustable legs add up to 160 mm on 60, 70, 80 and 90 cm cookers.
Height adjustable legs add up to 150 mm on 53 cm cookers.
The adjustable legs are screwed into the base of the cabinet and the height adjustment is
achieved by rotating the lower portion of the legs clockwise or anti-clockwise as appropriate.
REFER TO RELEVANT PAGE IN THIS MANUAL FOR INSTALLATION OF ANTI TILT BRACKETS
NOTE: Glem Gas Australasia Pty Ltd and their appointed agents decline any responsibilities
in the case of installation not according to these instructions.
INSTALLATION - ELECTRICAL CONNECTION
Before connecting the plug into the power socket, follow these instructions:
The electrical supply for the upright cooker must be a 240 Volt 50 Hz.
The fuse and electrical wiring of the dwelling must support the load of the appliance.
The 3-pin plug, used to connect the electricity, must be easily reached when the cooker
is in its installed position.
The upright cooker must be earthed. Connect the upright cooker to a properly earthed and
rated power socket, as appropriate.
The flexible cord of the upright cooker must not be subject to direct heat and must be
positioned after installation so that its temperature does not exceed 75°C.
IMPORTANT: If a power socket needs to be installed or relocated, the work must be done by a
licensed electrician.
In New Zealand the cooker must be connected to the supply by a supply cord fitted with an ap-
propriately rated plug that is compatible with the socket-outlet fitted to the final sub-circuit in the
fixed wiring that is intended to supply the cooking range.