30
BLUETTI
●User can set the Reserved capacity at 100% to let EP500 always be charged
to 100% capacity via both grid and solar power.
10.2.3. Time Control UPS
●Set the times of the EP500 to be charged via grid power and the times to run
loads from its battery.
Charge Time: set the time of EP500 when to be recharged by grid to avoid
the higher electricity bills charged.
Discharge Time: the time to generate power from its inside battery pack to
power the loads connected on AC output port of EP500 or Sub Panel
(optional purchase).
●Parameter Setting:
Battery SOC Low: When the remaining capacity of EP500 is under the preset
Battery SOC Low state, EP500 will stop powering loads connected to AC output port
of EP500 or Sub Panel.
Battery SOC High: The maximum capacity EP500 can be charged via grid, EP500
will be charged to 100% capacity via solar power or 2nd adapter only.