, WARNING - Risk of Fire
~
Any installation, service or repair work is to be done by
a Miele Service Technician. Any work done by an
unauthorized person could be dangerous.
~
Installation must conform with all local and national
codes and regulations.
~
Before installation, disconnect the dryer from the
electrical supply by shutting off the power, unplugging the
power cord or tripping the circuit breaker. Do not restore
power until installation is complete.
~
Be certain your appliance is properly installed and
grounded by a qualified technician.
~
For electrical safety this appliance must be grounded
z in accordance with local codes. It is imperative that this
basic safety requirement be met. If there is any doubt, have
the electrical system of the house checked by a qualified
electrician.
~
Do not damage, remove or bypass the safety
components, fixtures and control elements of this machine.
~
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
operation.
~
Ensure that there is adequate ventilation for operation in
the room where it is installed.
~
Do not operate the dryer in a room where cleaning
machines operate with solvents containing CFC. Vapors
turn into salt acid which may damage the laundry and
machine. When operated in adjoining rooms, there should
be no air exchange possible.
~
The exhaust must not be led into a chimney used by
another gas, coal or oil heated appliance. It must not be
connected to any gas vent, chimney, wall, ceiling, or
concealed space of a building. It should be directed by the
shortest route into the open air or into a suitable venting
duct. The duct must be designed and installed to
accommodate the high air throughput (as few bends and
as short a duct as possible and well shaped, leakproof
joints).
~
CAUTION: An unvented dryer produces combustible
lint. Exhaust outdoors!
~
No filters or louvers should be built into the exhaust
duct.
~
The connection between the exhaust ducting and the
dryer must be airtight.
~
Protect exhausts ducted into the open air against the
weather by a 90° downward angle.
~
To facilitate cleaning of the duct, cleaning flaps or
covers should be fitted on the bends wherever possible.
~
With upward sloping exhaust ducting a condensate
drain must be made at the lowest point.
~
Use only genuine Miele spare parts to replace faulty
components.
~
The minimum dimensions and distance required from
the wall, as shown in the installation diagram, must be
observed to allow service to be performed and the data
plate to be viewed.
~
Do not install the dryer where it is exposed to water
and/or the weather.
~
Install the dryer with adequate clearances for servicing
and proper operation.
~
See the "Installation - Exhaust, Air intake, Ventilation
cross sections and Steam" manual for more information.
SAVE THESE
INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS