Napoleon GVFT8N Torch VF Series Vent Free Natural Gas Fireplace

User Manual - Page 18

For GVFT8N.

PDF File Manual, 28 pages, Read Online | Download pdf file

GVFT8N photo
Loading ...
Loading ...
Loading ...
18
W415-0847 / B / 03.17.11
L1
L2
CABLE
CONNECTOR
ELECTRICAL BOX
(C/W GROUND SCREW)
ELECTRICAL
BOX COVER
(C/W 2 RECEPTACLES)
GROUND
WIRE NUTS
GROUND
SCREW
6.0 ELECTRICAL INFORMATION
!
WARNING
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SER-
VICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
ELECTRICAL CIRCUIT.
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA C22.1
CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE
ANSI/NFPA NO. 70 IN THE UNITED STATES.
It is not necessary to hard wire this appliance, however if accessories that do require power are being consid-
ered it is recommended to make your electrical connection during initial installation.
As illustrated, route a grounded 2-wire, 60HZ power cable to the junction box. At this point it must be strain
relieved and insulated.
10.1
Loading ...
Loading ...
Loading ...