Napoleon HDX40NT2 High Definition X Series Direct Vent Natural Gas Fireplace

User Manual - Page 24

For HDX40NT2.

PDF File Manual, 112 pages, Read Online | Download pdf file

HDX40NT2 photo
Loading ...
Loading ...
Loading ...
W415-1596 / 11.25.15
24
EN
COMBUSTIBLE FRAMING:
Sides, back, bottom of the
appliance
0” to stand-offs
COMBUSTIBLE FINISHING:
Sides 2” (51mm) to front edge of the appliance
Enclosure Top 84” (2134mm) from the bottom of the appliance
Recessed Depth 22 1/4” (565mm)
Sides of the vent pipe 2” (51mm)*
Bottom of the vent pipe 1” (25mm)
Top of vent pipe 2” (51mm)*
Ceiling 70” (1778mm) from the bottom of the appliance
* HORIZONTAL VENT SECTIONS: A minimum clearance of 1” (25mm) at the bottom and 2” (51mm) at the top
and sides of the vent pipe in all horizontal runs to combustibles is required except for clearances in appliance
enclosures. Horizontal vent sections within enclosures require a minimum clearance of 18” (457mm) at the
top of the vent pipe. See “MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use restop
spacer W010-1800 (supplied) where vent pipe penetrates combustible walls.
* VERTICAL VENT SECTIONS: A minimum clearance of 1” (25mm) all around the vent pipe on all vertical
runs to combustibles is required except for clearances in appliance enclosures. Vertical vent sections
within enclosures require a minimum clearance of 4” (102mm) to the sides of the vent pipe. See “MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use restop spacer W500-0367 (not supplied)
where vent pipe penetrates combustible ceilings or oors.
5.1 MINIMUM CLEARANCE TO COMBUSTIBLES
22 1/4"
565mm
40 3/4"
1035mm
22 1/4"
565mm
40 3/4"
1035mm
40 3/4"
1035mm
35 1/4"
895mm
47"
1094mm
16 9/16"
421mm
66 1/2"
1689mm
BACK WALL OF CHASE / ENCLOSURE
(INCLUDING ANY FINSIHING MATERIALS)
2"
51mm
2"
51mm
4"
102mm
4"
102mm
6"
152mm
INSIDE
CHASE
OUTSIDE
CHASE