APPLICATION | 69
Application Guidelines
'XHWRRXUSROLF\RIFRQWLQXRXVSURGXFWLQQRYDWLRQVRPHVSHFL¿FDWLRQVPD\FKDQJHZLWKRXWQRWL¿FDWLRQ
©
/*(OHFWURQLFV86$,QF(QJOHZRRG&OLIIV1-$OOULJKWVUHVHUYHG³/*´LVDUHJLVWHUHGWUDGHPDUNRI/*&RUS
PLACEMENT CONSIDERATIONS
Minimum 19-11/16
"
Obstacle just on the
air discharge side.
Where there are obstacles on both suction
and discharge sides (discharge side obstacle
is higher than the outdoor unit).
Minimum 19-11/16"
Minimum 11-13/16
"
Where there are obstacles above, and on both
suction and discharge sides (discharge side obstacle
is higher than the outdoor unit).
Maximum 19-11/16"
Minimum 11-13/16"
Minimum 39-3/8"
L
H
A
Table 54: Ratio among H, A, and L.
If a stand is necessary, it should be contained (not open
frame) to prevent the discharge air from short cycling.
LA
/+
/+ 29-1/32 inches
1/2 H < L 39-3/8 inches
H < L
6HW6WDQGDV/+
L
Minimum 39-3/8"
Minimum 39-3/8"
Maximum 19-11/16"
Minimum 11-13/16"
Where there are obstacles above, and on both
suction and discharge sides (discharge side obstacle
is lower than the outdoor unit).
H
³/´VKRXOGEHORZHUWKDQ
³+´,IDVWDQGLVQHFHV-
sary, it should be con-
tained (not open frame) to
prevent the discharge air
from short cycling.
Minimum 19-11/16"
Minimum 19-11/16
"
Minimum 39-3/8"
Obstacles above and on the
air discharge side.
Where there are obstacles on both suction
and discharge sides (discharge side obstacle
is lower than the outdoor unit).
Minimum 19-11/16"
Minimum 11-13/16"
Minimum 11-13/16"
Minimum 78-3/4
"
Minimum 23-19/32"
Minimum 39-3/8"
Series installation
Outdoor Unit