The fixed consumer piping outlet should be at
approximately the same height as the cooker
connection point, pointing downwards and
approximately 150mm to the side of the cooker. The
hose should be clear of the floor when the cooker is
in the installed position. Ensure that the safety chain
is installed correctly so that the chain prevents strain
on the hose connections when the cooker is pulled
forward.
If the connection is for natural gas the test point
pressure should be adjusted to 1.00kPa with the wok
burner operating at maximum.
GAS CONNECTION
If installing for use with LPG ensure that an AGA
approved gas regulator suitable for a supply pressure
of 2.75kPa is part of the tank supply and the test point
pressure is adjusted to 2.75kPa.
- There is a connection kit supplied with the cooker.
The extension tube must be attached to the inlet
elbow on the cooker. At the other end of the tube
attach the regulator (for Natural Gas) using the
brass conical adaptor with the sealing washer.
Use two spanners to tighten to prevent strain
on the inlet tube.
- It is recommended that an isolating valve and union
be fitted, to enable simple disconnection for servicing.
These are to be in an accessible location.
- Check connections are gas tight with soapy water or
other approved method.
- Under no circumstances use a naked flame in
checking for leaks.
- Check Gas Adjustments (refer installation - gas
checks and adjustments).
- When satisfied that the upright cooker is operating
correctly, instruct the customer in its safe operation.
Ensure the customer understands fully by having
them operate the upright cooker in all its functions.
N
A
T
G
A
S
L
P
G
G
A
S
Natural Gas
LPG Gas
OR
Gas Flow
Gas Flow Gas Flow
INSTALLATION - ELECTRICAL CONNECTION
Before connecting the plug into the power socket, follow these instructions:
Theelectricalsupplyfortheuprightcookermustbea240Volt50Hz.
Thefuseandelectricalwiringofthedwellingmustsupporttheloadoftheappliance.
The3-pinplug,usedtoconnecttheelectricity,mustbeeasilyreachedwhenthe
upright cooker is in its installed position.
Theuprightcookermustbeearthed.Connecttheuprightcookertoaproperly
earthed and rated power socket, as appropriate.
Theexiblecordoftheuprightcookermustnotbesubjecttodirectheatandmustbe
positioned after installation so that its temperature does not exceed 75°C.
IMPORTANT: If a power socket needs to be installed or relocated, the work must be
done by a licensed electrician.
IMPORTANT: For models supplied without a plug a means for disconnection shall
be incorporated in the fixed wiring according to the wiring rules of the local electrical
authorities.
In New Zealand the cooking range must be connected to the supply by a supply cord
fitted with an appropriately rated plug that is compatible with the socket-outlet fitted to
the final sub-circuit in the fixed wiring that is intended to supply the cooking range.
INSTALLATION - GAS CONNECTION
These technical instructions have been prepared for use by Authorised persons. This unit
MUST ONLY BE INSTALLED BY AN AUTHORISED PERSON – PROOF IS REQUIRED
FOR WARRANTY SERVICE CLAIMS.
The cooker has been manufactured with Natural Gas injectors fitted. For use with LPG
the cooker must be converted. The conversion kit is supplied. Information on converting
the cooker is included with these instructions.
The requirements of the local gas and electrical authorities must be adhered to,
consult AS5601 as appropriate.
Gas inlet fitting is 1/2” BSP (male) thread.
This appliance can be connected with rigid pipe as specified in AS5601 table 3.1.
This appliance is approved for hose connection in compliance with AS5601, clause
5.12.1.8. The flexible hose must comply with AS/NZS 1869 (AGA Approved), 10mm
ID, class B or D, between 1 – 1.2 m long and in accordance with AS5601 for a high
level connection. The hose should not be subjected to abrasion, kinking or permanent
deformation and should be able to be inspected along its entire length. Unions’
compatible with the hose fittings must be used and all connections tested for gas leaks.