Loading ...
Loading ...
Loading ...
26 27
1.
Location of gas inlet
Bottom rear of upright cooker:
6
0 mm from RH side
400 mm from base without legs installed
2.
Electrical connection
Connection is by means of flexible cord and plug except for electric models which
must be hard wired.
3.
Overall dimensions of upright cooker
Depth over cabinet 600 mm
Height over hob 760/750 mm (CHECK MODEL)
Height over splashback 820 mm
534 series width 530 mm
664 series width 598 mm
865 series width 798 mm
965 series width 898 mm
765 series width 698 mm
ML76 width 698 mm
ML96 width 898 mm
ML106 width 998 mm
On models with removable legs add up to 150 mm.
The adjustable legs are screwed into the base of the cabinet and the height adjustment
is achieved by rotating the lower portion of the legs clockwise or anti-clockwise as
appropriate.
Glem Gas Australasia Pty Ltd and their appointed agents decline any responsibilities in
the case of installation not according to these instructions.
280mm
Rangehoods
Rangehoods and overhead exhaust fans must be installed according to manufacturers’
instructions but in no case shall clearance from hob burners be less than 600 mm for a
rangehood and 750 mm for overhead exhaust fan.
Ventilation
A cooker should not be installed in any room which has a volume less than 5.6 cu. m.
(200 cu. ft.). If the room is between 5.6 Cu. m. (200 cu. ft.) and 11.2 cu. m. (400 Cu. ft.)
in volume, provision must be made for permanent ventilation. Above 11.2 cu. m. (400 cu.
ft.) volume, no special provision needs to be made unless other gas burning appliances
are installed in the same room. Ventilation must always be provided if a cooker is
installed in a cellar or a basement. The manufacturer does not accept damage caused
directly or indirectly by failure to comply with the above.
750mm
600mm
Allow a 5mm gap
on each side
Loading ...
Loading ...
Loading ...