Manifold System leaks at connections
Check Solution
Connections are loose Retighten connections
O-ring is out of place, damaged,
or missing
Replace o-ring in proper place
Water pressure exceeds 80 PSI
Install a pressure regulator
upstream of manifold
The valve does not open electrically (but opens using the bleed screw)
and sprinkler timer is functioning
Check Solution
Individual sprinkler wire
pulls out easily
Untwist wires and follow Step 5 in
“Speed-Seal” Connection
Bare individual sprinkler wire
extends beyond protective
membrane
Remove wire and ensure the bare
wire is not shorter than 7/8" and
no more than 1" in length. Untwist
wires and follow Step 5 in “Speed-
Seal” Connection
Individual Sprinkler wires are
held firmly in place but are not
contacting bare wire
Ensure the bare sprinkler wire is
not shorter than 7/8" and no more
than 1" in length.