Loading ...
Loading ...
Loading ...
5
The Standalone System consists of four main elements:
1. Proflame Digital Fireplace Control (DFC)
2. Proflame 880, or 886 families of gas valves
3. Pilot assembly
4. Proflame DFC wiring harness to connect the DFC to the gas valve, and to the pilot burner
The GTMS System consists of eight main elements:
1. Proflame GT Series Transmitter
2. Proflame GT Series Receiver
3. Proflame Digital Fireplace Control (DFC)
4. Proflame Gas Valve 885 family (also the 880, 886 families are compatible)
5. Pilot assembly
6. Split Flow Control (optional)
7. Proflame GT Series wiring harness to connect the Receiver to the DFC wirings, to the Gas valve
stepper motor, and to the Split Flow Control
8. Proflame DFC wiring harness to connect the DFC to the gas valve, and to the pilot burner
The GTMFS System consists of nine elements:
1. Proflame GT Series Transmitter
2. Proflame GT Series Receiver
3. Proflame Fan Control Module (FCM)
4. Proflame Digital Fireplace Control (DFC)
5. Proflame Gas Valve 885 family (also the 880, 886 families are compatible)
6. Pilot assembly
7. Split Flow Control (optional)
8. Proflame GT Series wiring harness to connect the Receiver to the FCM, to the DFC wirings, to
the Gas valve stepper motor, and to the Split Flow Control
9. Proflame DFC wiring harness to connect the DFC to the gas valve, and to the pilot burner.
Supply voltage/frequency: 120 V / 60 Hz
Ambient temperature ratings: 0 to 60 °C (32 to 140 °F)
Three wires bus: two wires to provide DC voltage to the receiver;
one wire gives uni-directionally signal from the receiver
Output voltage/frequency/current: 120 V / 60 Hz / 5 A
Aux switched output: 120 V / 60 Hz / 2 A
Fan speed output: 120 V / 60 Hz / 1 A
FAN CONTROL MODULE (PROFLAME GTMF & GTMFS only)
Supply voltage DC IN: 7Vdc - 200mA max (Class 2 power supply)
BB IN: 6Vdc - 200mA max (four 1.5V size AA batteries)
Ambient temperature ratings -18 to +80 °C (0 to +176 °F)
Spark voltage
>15kV
Spark energy
>0,7mJ
Spark frequency
1Hz
Tested gas types the system has been tested both for NG, and LPG gas types/mixtures
Pilot ignition source
Intermittent/Continuous
DFC CONTROL BOARD
SYSTEM COMPONENTS