Remote Actuated 120V Auxiliary Outlet (Proflame GTMF & GTMFS only)
The auxiliary function controls the AUX power outlet on the Fan Control Module. To activate this
function use the Mode Key (fig. 1) to index to the AUX icon (fig. 16 & 17).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the
outlet off. A single “beep” will confirm the reception of the command.
Fig. 16
Fig. 17
Fig. 14
Fan Speed Control (Proflame GTMF & GTMFS only)
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled
by the Proflame system. The fan speed can be adjusted through six (6) speeds. To activate this fun
-
ction use the Mode Key (fig.1) to index to the fan control icon (Fig. 14). Use the Up/Down Arrow
Keys (
Fig.1) to turn on, off or adjust the fan speed (fig. 15). A single “beep” will confirm reception
of the command.
Fig. 15