SPECIFICATIONS
Model Input Rating Input Rating Thermostat Weight Dimension Fan CFM
BTU/H HIGH BTU/H LOW in pounds in inches Output
RCE-329A-N 10,000 3,000 YES Height: 17 7/16" High:92
17.6 _/idth: 16 9/16"
RCE-329A-P 10,000 3,400 YES Depth: 8 Low:53
"-N" Models are for Natural Gas. (Inlet Pressure within 5.5"--10.5"W.C.)
"-N" Models manifold pressure: 3.9"W.C.
"-P" Models are for L.P. Gas. (Inlet Pressure within 6.3" --13" W.C.)
"-P" Models manifold pressure: 5.2"W.C.
Gas connection pipe size 1/2" N.P.T. all models.
I
SAFETY DEVICES
Overheat Switch
When the heater gets too hot during operation (for example when the filters or air outlet louvers are
blocked) this device turns the gas off automatically. Remove cause of overheat (clean filters) allow
heater to cool, then re-ignite.
Fuse
The electrical circuits are protected by a fuse. When the fuse blows, the heaters will not operate at
all. The fuse must be replaced by an authorized person.
Flame Failure Device
This device automatically cuts off the gas supply to the heater in the event of a gas failure. To
restore the gas supply to the heater, turn it off, then follow the ignitionprocedure.
Oxygen Depletion Safety Device
Ifthe oxygen level in the room drops below a pre-set limit, this device cuts the gas supply off to the
heater. If the oxygen depletion device operates, tum the heater off, ventilate the room, then follow
the ignitionprocedure to re-light. Heater will not re-light until room is fully ventilated.
Tilt Switch
If the heater isknocked over, the tilt switch will cut the gas supply off. The fan keeps running. To
restore the gas supply, stand the heater upright, turn itoff then follow the ignition procedure. The tilt
switch may also operate if the heater isjolted or picked up while in operation.
Power Failure
In the event of a power failure or power cut, the gas valves will automatically close. After the power
is re-instated the appliance must be restarted manually.