15
Installation
Wall Ther-
mostat Cable
12V DC Power Cable
LED Cable
Fig. 14
16. Connect the wall thermostat cable and
12VDC power cable to the control box.
17. Connect the LED cable from the ADB
shroud to the control box. (Fig. 15)
LED Cable
LED Cable
Fig. 15
18. Install the Air Distribution Box (ADB)
shroud over the mounting frame and
fix with 4 self-tapping screws.
NOTE: Make sure the “THIS WAY
FRONT” mark is facing front (the
direction of the vehicle) while
installing. (Fig. 16)
Fig. 16
19. Align the filter tabs with mating
notches and push to snap the filters
into the ADB shroud. (Fig. 17)
Fig. 17
20. Align the decoration plate tabs
with the mating notches on the
ADB shroud and push to snap the
decoration plate into place. (Fig. 18)
Fig. 18
21. Your new rooftop air conditioner has
now been fully installed in the RV
roof. (Fig. 19)
Fig. 19
Based on the wall thermostat version
you selected. Please refer to the
separate instruction manual on how to
operate your RV air conditioning system.