The auxilia[ T controls are located behind the room cabinet on the front of
the unit control box. The factory settings will be in the DOWNposition. The
owner is responsible for checking switches and ensuring they are in the
desired position.
*All E
UP:Fancycle
DOWN:F
RemoteCq
123456
UP
DOWN
Load Shedding)
(Class 2)
*Not on Model 2200 Series
1
B
23456
UP
IIaaaaIoow.
Auxiliary Controls
Down--Continuous Fan
Up--Cycle Fan
The fan switch #2 is located behind
the room cabinet.
This switch is set at continuous fan
(DOWN) at the factory to provide
continuous fan operation in cool
or heat modes. Leaving the switch
in the continuous fan setting allows
continuous circulation of room air
and will resuh in a more balanced
temperature throughout the room.
If you want the fan to cycle on
and offwith the compressor or
with the heater, move the switch
to cycle fan (UP).
123456
UP
FIBFIBFIII ]oowN
Switch #6 controls the Freeze
Sentinel. When the switch is DOWN,
the Freeze Sentinel automatically
turns on the resistance heater and
fan if the room temperature (sensed
at the unit) drops to approximately
40 ° F. It will turn the heater offwhen
the temperature reaches about 45 ° F.
The unit leaves the factory with
the Freeze Sentinel in the DOWN
(on) position.
The Freeze Sentinel helps prevent
plumbing damage in the room due
to sub-freezing temperatures.
If the Freeze Sentinel is set, it is
active as long as power to the
unit is on.
NOTE: The owner is responsible for
checking the Freeze Sentinel switch
and ensuring it is in the desired
setting. 7