Low Voltage Connectors & Auxiliary Controls
NOTE: The owner is responsible for checking all switches and ensuring they are set in the desired setting.
The Electric Heat Option switch #1 increases
the Zoneline air temperature by using electric
heat only. The heat pump is not used to produce
any heat.
Using the Electric Heat Option is much more
expensive than heating with the heat pump only.
To set the Electric Heat Option, move switch to
the O/V (up) position.
123456
UP
BBBBB lDowN
Auxiliary controls
i! Temperature Limiting
Temperature limiting can reduce energy costs by
limiting the lowest temperature that can be set
fl)r cooling and the highest temperature that can
be set fi)r heating.
Limiting the maximum and minimum settings
prevents users from turning the control to the
extreme heat or cool positions.
The normal fifll range of the temp control is
approximately 62 ° F to 85 ° F. The control range
may be narrowed by the use of the temperature
limiting screws located behind the control panel.
®
@
®
Limits
heat
temp
®
®
temp
Eachposition equals
approximately 3° F
17