VC Series Manual 35
Temperatures Available with a Controller
The water heater can deliver water at only one temperature seng at a me. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/O” buon
for 5 seconds while the water heater is OFF.
These temperatures are suggesons only:
* Temperature sengs from 125-140 °F (52-60 °C) are available by seng switch 6 to ON in the SW1 Dip
switch (tan switches). These models have a default maximum temperature of 120° F (49° C) and an opon
(switch 6) to increase the maximum temperature to 140 °F (60 °C).
DO NOT adjust the other switches unless specically instructed to do so.
WARNING
• Kitchen 120 °F (49° C)
• Shower 98 - 110 °F (37 - 43 °C)
• Bath Fill 102 - 110 °F (39 - 43 °C)
Temperature Sengs Available (Fahrenheit °F)
RL75i, RL75e
98 100 102 104 106 108 110 115 120
125
*
130
*
135
*
140
*
150
**
160
**
RL94i, RLX94i,
RL94e
185**
Celsius °C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85
** These sengs require the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91-2 controller in a
residenal dwelling will reduce the warranty coverage to that of a commercial warranty applicaon.
Alternate Temperature Sengs
A dierent range of temperature sengs is available by seng switches 2 and 3 of the SW2 dip switch (white
switches) to ON. The table below shows the sengs available with the MC-91-2 and MCC-91-2 controller.
Alternate Temperature Sengs Available (Fahrenheit °F)
RL75i, RL75e
110 115 120 125 130 135 140 145 150 155 160
RL94i, RLX94i, RL94e
165 170 175 180 185
Celsius °C 43 46 49 52 54 57 60 63 66 68 71 74 77 79 82 85
MC-91-2
MCC-91-2
MC‐91‐1, MCC‐91‐1, MC‐100V‐1, and BC‐100V‐1 controllers are not compable with
Alternate Temperature Sengs. Alternate Temperature Sengs are for commercial
applicaons only.
DO NOT use the MC‐91‐1, MCC‐91‐1, MC‐100V‐1, or BC‐100V‐1 controllers when dip
switches 2 and 3 (white switches) are in the ON posion.
WARNING