Rinnai RL75EP Tankless Hot Water Heater, 7.5 GPM, Propane, Outdoor Installation

Operation Manual - Page 11

For RL75EP. Series: VC
Also, The document are for others Rinnai models: REU-VC2528FFUD-US, REU-VC2528FFUD-US(A), REU-VC2737FFUD-US, REU-VC2837FFUD-US

PDF File Manual, 94 pages, Read Online | Download pdf file

RL75EP photo
Loading ...
Loading ...
Loading ...
VC Series Manual 11
Freeze Protecon
Make sure that in case of freezing weather that the
water heater and its water lines are protected to
prevent freezing. Damage due to freezing is not
covered by the warranty.
With electrical power and gas supplied, the water
heater will not freeze when the outside air
temperature is as cold as –22°F (-30°C) for indoor
models or is as cold as –4°F (-20°C) for outdoor
models, when protected from direct wind exposure.
Because of the wind-chilleect, any wind or
circulaon of the air on the unit will reduce its ability
to protect itself from freezing.
In the event of a power failure and/or gas
interrupon at temperatures below freezing the
water heater should be drained of all water to
prevent freezing damage. In addion, drain the
condensate trap and drain line.
Loss of freeze protecon may result in water damage
from a burst heat exchanger or water lines.
The unit may be drained manually. However, it is
highly recommended to:
drain down solenoid valves be purchased and
installed that will automacally drain the unit if
power is lost. These are available in a kit,
104000059. (The condensate trap is not aected
by the auto drain down solenoid valves and will
have to be manually drained.)
a surge protector with terminals be purchased
and installed which allows the solenoid valves to
operate if the unit is disabled due to a diagnosc
code. This is available as 104000057.
In addion, the solenoid valves should be connected
electrically to a surge protector with terminals. This
allows the solenoid valves to operate if the water
heater is disabled due to a diagnosc code.
The freeze protecon features will not prevent the
external piping from freezing. It is recommended that
hot and cold water pipes be insulated. Pipe cover
enclosures may be packed with insulaon for added
freeze protecon.
Maximum vent length
(indoor models only)
1. Determine the number of 90 degree elbows in
the vent system. (Two 45 degree elbows count as
one 90 degree elbow.)
2. Refer to the table to nd the maximum vent
length based on the number of elbows.
3. Adjust switch No. 1 in the SW1 DIP switch (tan
switches) if required by the applicable note.
If the length is greater than 21  (6.4 m) then
move switch No. 1 (SW1) to OFF.
If the length is greater than 15  (4.6 m) then
move switch No. 1 (SW1) to OFF.
If the length is greater than 9  (2.7 m) then move
switch No. 1 (SW1) to OFF.
Move switch No. 1 (SW1) to OFF.
Example: If you have one elbow then your maximum
vent length is 35 feet (10.7 m). If your
actual length is greater than 15  (4.6 m)
then move switch no. 1 (SW1) to OFF.
Number of
90° Elbows
Maximum vent length
0 41  (12.5 m)
1 35  (10.7 m)
2 29  (8.8 m)
3 23  (7.0 m)
4 17  (5.2 m)
5 11  (3.4 m)
6 5  (1.5 m)
If you have a longer vent length (see number 3
regarding max. vent length), switch No. 1 is required
to be in the OFF posion. This ensures the water
heater will run properly. Blocked ue diagnosc
codes and shutdowns may result if switch No. 1 is not
in the correct posion.
NOTICE