Loading ...
Loading ...
Loading ...
VC Series Manual 25
Technical Data
Specicaons
* Minimum ow may vary slightly depending on the temperature seng and the inlet water temperature.
Minimum acvaon ow is 0.4 GPM (1.5 L/min).
Our products are connually being updated and improved; therefore, specicaons are subject to change without prior noce.
The maximum inlet gas pressure must not exceed the value specied by the manufacturer. The minimum value listed is for the
purpose of input adjustment.
RL75i RLX94i RL94i RL75e RL94e
Minimum Gas Consumpon Btu/h 10,300
Maximum Gas Consumpon Btu/h 180,000 192,000 199,000 180,000 199,000
Hot water capacity (Min - Max) *
0.26 - 7.5 GPM
(1.0 - 28.5 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
0.26 - 7.5 GPM
(1.0 - 28.5 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
Temperature Seng (no controller) 120° F (49° C) or 140° F (60° C)
Maximum Temp Seng (residenal) Selectable at 120° F (49° C) or at 140° F (60° C)
Maximum Temp Seng
(MCC-91 controller)
160° F (71° C) 185° F (85° C) 185° F (85° C) 160° F (71° C) 185° F (85° C)
Minimum Temperature Seng 98° F (37° C)
Weight 45.6 lb (20.7 kg) 46.3 lb (21.0 kg) 46.3 lb (21.0 kg) 43.6 lb (19.8 kg) 44.3 lb (20.1 kg)
Noise level 49 dB (excluding start up or shutdown)
Electrical Data
Normal 76 W 97 W 97 W 57 W 65 W
Standby 2 W
An-frost Protecon 120 W 104 W
Max Current
Without recirculaon pump: 4 A
With recirculaon pump: 8 A (exact value depends on the pump)
Fuse 10 A
By-Pass Control Fixed Electronic Electronic Fixed Electronic
Gas Supply
Pressure
Natural Gas 4.0 - 10.5 inch W.C.
Propane 8.0 - 13.5 inch W.C.
Type of Appliance Direct Vent, Tankless, Temperature controlled connuous ow gas hot water system
Connecons Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignion System Direct Electronic Ignion
Electric Connecons
Appliance: AC 120 Volts, 60Hz.
Temperature Controller: DC 12 Volts (Digital)
Water Temperature Control Simulaon Feedforward and Feedback
Water Supply Pressure Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure 150 PSI
Temperature Control Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
Cered for installaon in
manufactured (mobile) homes
Yes
Complies with South Coast Air Quality
Management District 14 ng/J or 20
ppm NOx emission levels
Yes Yes No Yes Yes