Operating Instructions and Owner’s ManualMr. Heater, Inc.| Forced Air Propane Construction Heater
MAINTENANCE AND STORAGE
1. Theheatershouldbeinspectedbeforeeachuse,andatleast
annuallybyaqualifiedperson.
2. Beforeeachuse,checkthesoft"O"ringsealatthebullnose
ofthePOLfitting.Ifthe"O"ringiscut,scuffed,orotherwise
damaged,replaceitwithpartnumber73786.
3. TurnoffthegasattheLP-gassupplycylinder(s)whenthe
heater is not in use.
4. Whentheheateristobestoredindoors,theconnection
betweentheLP-gassupplycylinder(s)andtheheatermust
bedisconnectedandthecylinder(s)removedfromtheheater
andstoredoutofdoorsandinaccordancewithChapter5of
thestandardforStorageandHandlingofLiquefiedPetroleum
GasesANSI/NFPA58andCSAB149.1,NaturalGasand
PropaneInstallationCode.
SERVICING
Ahazardousconditionmayresultifaheaterisusedthathasbeen
modifiedorisnotfunctioningproperly.Whentheheaterisworking
properly:
• Theflameiscontainedwithintheheater.
• Theflameisessentiallybluewithperhapssomeyellowtipping.
•
Thereisnostrongdisagreeableodor,eyeburning,or
other
physical discomfort.
• Thereisnosmokeorsootinternalorexternaltotheheater.
• Therearenounplannedorunexplainedshutdownsofthe
heater.
Thepartslistsandwiringdiagramshowtheheaterasitwas
constructed. Do not use a heater which is different from that
shown.Inthisregard,useonlythehose,regulatorandcylinder
connectionfitting(calledaPOLfitting)suppliedwiththeheater.
IMPORTANTMatchthecolorstripeonthehangtagattachedto
the hose assembly with the color on the label located near the
propaneinletfittingontheheater.Donotusealternates.Forthis
heater,theregulatormustbesetasshownin"specifications".
Ifthereisanyuncertaintyabouttheregulatorsetting,haveit
checked.
Aheaterwhichisnotworkingrightmustberepaired,butonlybya
trained,experiencedserviceperson.
In-warrantyproductswillberepairedwithnochargeforeitherparts
or labor. Please include a brief statement indicating date, place of
purchase, the nature of the problem and proof of purchase.
Out-of-warrantyproductswillberepairedwithachargeforparts
and labor.
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1. Checktheheaterforpossibleshippingdamage.Ifanyis
found, immediately notify the factory.
2. Followallofthe"Precautions".
3. ConnectthePOLfittingofhoseandregulatorassemblytothe
propanecylinderbyrotatingthePOLnutcounterclockwiseinto
thepropanecylinder'svalveoutletandsecurelytightenwitha
wrench.
4. Connectthehosetotheheaterbyrotatingthehosefitting
clockwise.
5. Securelytightenallgasconnections.
6. Openthecylinder'sgasvalveandcheckallgasconnections
withasoapandwatersolution.DONOTUSEAFLAME.
7. Connectpowercordtowell-grounded115V,60Hz,1Øsource
of power.
8. Whenusinganextensioncord,makecertainthatitisa3-wire
(grounded)cordofproperwiresize.
START
1. Beforeheaterignition,alwaysallowheaterfan(blower)torun
for20secondstopurgefuel.
2. Slowlyopenthemainvalveatpropanecylinder.
3. Depressthefuelvalvebuttontolighttheheater.
4.
Aftertheheaterlights,keepthegasvalvebuttondepressed
for15seconds,
thenrelease,andtheheaterwillcontinue
tooperate.
5. Adjustburnratebysettingcontrolknobtodesiredlevel.
6. Nothermostatusablewiththeseunits.
STOP
1. Securelyclosevalveonthepropanecylinder.
2. Continuetooperateheateruntilallfuelinthehosehas
burned.
3. Unplugthepowercord.
RESTART AFTER SAFETY SHUTDOWN
1. Securelyclosevalveatpropanecylinder.Unplugheater.
2. Wait5minutes.
3. Restartfollowing"Start"procedure.