5
standard checklist
1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in flame appearance from “HI” to “LO” is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certified for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and must be installed.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1 rates and efficiencies
BL36-1 BL46
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT) 0-4,500 0-4,500 0-4,500 0-4,500
Max. Input (BTU/hr) 16,000 16,000 24,000 24,000
Min. Input (BTU/hr) 10,500 10,500 17,500 18,500
P4 51.7% 51.7% 50.3% 50.3%
Min. Inlet Gas Supply
Pressure
4.5” w.c. (11mb) 11” w.c. (27mb) 4.5” w.c. (11mb) 11” w.c. (27mb)
Max. Inlet Gas Supply
Pressure
13” w.c. (32mb) 13” w.c. (32mb) 13” w.c. (32mb) 13” w.c. (32mb)
Manifold Pressure (Under
Flow Confictions)
3.5” w.c. (9mb) 3.5” w.c. (9mb) 3.5” w.c. (9mb) 3.5” w.c. (9mb)
Installer: please fill out the following information
Customer:
Address:
Date of Installation:
Location of the appliance
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas: BL36NTE-1
BL46NTE
Propane: BL36PTE-1
BL46PTE