Napoleon BL36NTE1 Ascent Linear Series Direct Vent Natural Gas Fireplace

User Manual - Page 32

For BL36NTE1.

PDF File Manual, 124 pages, Read Online | Download pdf file

BL36NTE1 photo
Loading ...
Loading ...
Loading ...
W415-1705 / 06.07.17
EN
32
venting installation
5.6 vertical through existing chimney
!
WARNING
Risk of fi re.
Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure.
Installation in a combustible enclosure could result in a fi re.
This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full
length of a masonry chimney.
The fl ex liners accommodate any contours of a
masonry chimney, however, it is necessary to keep
the fl exible liners as straight as possible. The inlet
air collar of the termination cap must be connected
to the air intake fl ex liner and the exhaust collar
must be connected to the exhaust fl exible liner.
Both Simpson Duravent and Selkirk co-linear to
co-axial adaptors have been approved on this
appliance (NOTE: A vent adaptor will be required
directly off the appliance).
Follow vent manufacturer’s installation
instructions.
Different manufacturer’s venting components
must not be combined. Once the preferred
manufacturer’s appliance adaptor has been
attached, the remainder of the system
must be that of the same manufacturer.
The only exception to this rule is to use
Wolf Steel’s approved 3” (76.2mm) fl ex
liner and co-linear termination.
AIR
INTAKE
EXHAUST
FLUE
FLEX
LINER
* 40 FT (12.2m)
MAX.
10 FT (3.1m)
MIN
COAXIAL TO
CO-LINEAR
ADAPATOR
APPLIANCE
VENT ADAPTOR
TERMINATION
* Measured from appliance fl ue collar
to termination fl ue collar