9
3. Check the Refrigeration Circuit
Visually check that the refrigerant lines do not rub or touch other lines or surfaces and
that the condenser fan blade turns freely.
• Check that the compressor is snug on all mounting pads.
4. Position the Appliance and Lock the Front Casters
The front casters on the appliance are lockable. After positioning the appliance in its nal
location, lock the front casters.
5. Install the Shelves
Shelf support clips are provided in the accessory pack.
1. Place the shelf support clips into the pilasters (4 shelf support
clips per shelf). Indexing holes are provided on the pilasters
in evenly spaced intervals to assist you in positioning the
support clips at the same height. See Fig. 3.
2. Place the shelves in position on the shelf support clips.
D. Door Reversal
This appliance is provided with a cabinet design which, after being delivered to the
installation location, permits changing of the door swing from left to right or right to left.
To change the door swing, an HS kit from your local Hoshizaki distributor is required.
See the table below. NOTICE! Improper installation of the HS kit may result in the
doors not closing completely and/or the gaskets not sealing correctly. For further
details, contact your local Hoshizaki distributor or Hoshizaki Technical Support at
1-800-233-1940.
Door Type Convert HS Kit Number
Glass
Right Hinge to Left Hinge HS-5045
Left Hinge to Right Hinge HS-5046
Solid
Right Hinge to Left Hinge HS-3725
Left Hinge to Right Hinge HS-3726
Shelf
Support
Clip
Indexing
Holes
Pilaster
Shelf
Fig. 3
Loading ...
Loading ...
Loading ...