C. Controls and Adjustments
1. Temperature Display
The cabinet temperature is displayed on the control module. See Fig. 5. The display
default is °F, but it can be changed to read °C. To change, see "II.C.3. Changing the
Temperature Display Scale (°F or °C)."
2. Adjusting the Temperature Setpoint
The temperature setpoint is the value for the average cabinet temperature. The
temperature differential for the compressor to turn on and off is ±3°F (±1.7°C) of the
temperature setpoint. For example, for a refrigerator temperature setpoint of 36°F (2°C),
the compressor comes on at 39°F (3.7°C), and the compressor goes off at 33°F (0.3°C).
If necessary, adjust the temperature setpoint temperature as follows:
1) To change the temperature setpoint, press and hold the up button briey and then
release. The current temperature setpoint appears. Press the up or down button until
the desired value is displayed. After a few seconds, the display returns to the current
cabinet temperature and the temperature setpoint is saved.
• For refrigerators, the temperature setpoint is adjustable between 34°F and 52°F (1°C
and 11°C). The factory default is 36°F (2°C).
• For freezers, the temperature setpoint is adjustable between -15°F and +12°F (-27°C
and -11°C). The factory default is -4°F (-20°C).
ECO
°C
°F
SC
V
V
Fig. 5
Up
Button
Down
Button
Front
Panel
SC
Button
Manual
Defrost
Button
Control Module
Compressor Icon
Defrost
Icon
Evaporator Fan
Motor Icon
Alarm
Icon
Loading ...
Loading ...
Loading ...