15
D. Control Module Icons
Control module icons inform you of energized components and if the appliance is in
alarm.
Control Module Icons
Icon Meaning
Compressor
Compressor running.
Defrost
Appliance is in defrost cycle. See "II.E. Defrost" for details.
Evaporator Fan Motor (Icon is Applicable to Freezers Only)
Evaporator fan motor is running. Evaporator fan motor de-energizes when door is open.
Alarm
Appliance is in alarm. See "II.G. Alarm Safeties" for details.
3. Changing the Temperature Display Scale (°F or °C)
To change the temperature display scale, follow the steps below. The factory default is °F.
1) Press and hold both the up and down buttons for 5 seconds. "PAS" appears briey in
the display, then "000" appears.
2) Press the up button to change the display to "001".
3) Press the SC button. "
EHE
" appears in the display. Press the up or down button until
"diS" is displayed.
4) Press the SC button. "CFu" appears in the display. Press the SC button again. The
current temperature display scale setting appears. Press the up or down button to
change the temperature display scale.
5) Press the SC button to save the setting. Wait 1 minute or press the manual defrost
button twice to return to the temperature display.
4. Light Switch for Glass Door Models
Glass door models feature a uorescent light that is controlled by a light switch located
on the bottom of the front panel. See Fig. 6.
Fig. 6
Light Switch for
Glass Door Models
Front Panel
Loading ...
Loading ...
Loading ...