WARNING
The stand-offs located on the back of
the insert must not be removed when
installing the insert into a built-in
combustible enclosure.
Outside air is mandatory for a
combustible built-in enclosure install.
INSTALLATION INTO A COMBUSTIBLE ENCLOSURE
When installing the insert as a "Built-in" heater, it is
important to maintain the clearances to combustibles.
See "Minimum Clearances to Combustibles" section.
1) FRAMING
A. Install floor protection.
B. Frame structure maintaining clearances. Locate and frame openings for both the exhaust and
outside air. Outside air is mandatory for "Enclosure" installations.
C. Refer to the vent manufacturer's installation instructions and to "General Venting" section.
Connect the vent.
D. Install surrounding panel. See "HP22I Finishing - surrounding Panel Installation" section.
E. Consideration must be taken during installation that removal of the insert is necessary for
inspection and annual maintenance. Install the vent cap.