Installation and Operation Manual - Wood Stove
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model
Escape 1800
(DB03102, DB03105, DB03111 and DB03112)
Fuel Type
Dry Cordwood
Recommended heating area (sq. ft.
.
)
1
500 to 2,100 ft
2
(47 to 195 m
2
)
Total firebox volume 2.4 ft
3
(0.068 m
3
)
Loading volume EPA
2.02 ft
3
(0.057 m
3
)
Maximum burn time
1
8 hours
Maximum heat output (dry cordwood)
2
75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.)
2 3
14,8000 BTU/h to X28,600 BTU/h
(4.34 kW to 8.38 kW)
Average overall efficiency
3
(Dry cordwood)
69 % (HHV)
4
74 % (LVH)
5
Optimum efficiency
6
77 %
Average particulate emissions rate
7
1.54 g/h (EPA / CSA B415.1-10)
8
Average CO
9
89.4 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other performances are based on
a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efficiency at a specific burn rate (LHV).
7
This appliance is officially tested and certified by an independent agency.
8
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. Based on ALT-125 sent by EPA on
February 28th, 2018.
9
Carbon monoxide.
Loading ...
Loading ...
Loading ...