42
PLEASE NOTE: EL22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND EL22-I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
English
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Set Temperature Memory:
1. This model can memorize and save the last set temperature on the remote control with
“priority”.
2. If no remote control has “priority”, the set temperature of the unit will be the same as the
set temperature of the remote control which starts the water heater.
• This water heater contains an electronically controlled
thermostat. From the factory, the temperature range
is between 90°F and 140°F.
• The remote control is factory preset to 110°F.
• To turn the remote control ON or OFF, press the
POWER button for more than 3 seconds.
• To adjust the temperature to a required setting,
in“priority” mode, press the UP or DOWN temperature
button. Press and hold UP or DOWN to raise or lower
the temperature continuously.
• When the unit is in use, the set temperature can
increase to 122°F, but there is no limit to temperature
decrease. To increase the temperature more than
122°F, the water will need to be shut o rst.
NOTICE: If inlet water temperature is high, and set
temperature is low, the actual temperature might be higher
than the set temperature, and vice versa.
Please Note: It is recommended that you turn o the display
illumination by activating the screen saver after adjusting the
thermostat to your desired temperature.
DANGER: There is a hot water
scald potential if the temperature
is set too high. Households with
small children, disabled, or elderly
persons may require a 120°F. or
lower temperature setting to
prevent contact with HOT water.
Output temperature of water is regulated by setting
the temperature on the front of the remote control.
Safety factors should be considered when selecting
the water temperature setting of the water heaters
remote control. The remote control was set at 110°F
before the water heater was shipped from the
factory. This is the recommended starting point.
Water temperatures above 120°F can cause severe
burns or death from scalding. The thermostat is
adjusted to its lowest temperature position when
shipped from the factory.
Be sure to read and follow the warnings outlined in
this manual and on the label located on the water
heater.
Mixing valves are available for reducing point of use
water temperature by mixing hot and cold water in
branch water lines.
Procedures for adjusting the thermostat for
energy ecient operation at the minimum water
temperature setting consistent with the consumers
needs.
Contact a licensed plumber or the local plumbing
authority for further information. See page 4 for
details.
Water Temperature Setting
Water Temperature
120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Table courtesy of Shriners Burn Institute
• The display will read the set temperature if the water
heater is not in use or there is no water ow. If the
water heater is in use or has water ow, the display
will read the actual temperature. To view the set
temperature in this condition, press UP or DOWN and
the set temperature will ash for 3 seconds.
• The hottest temperature water will be at the hot water
faucet closest to the water heater
• Always remember to test the water temperature with
your hand before use and remember that hotter water
increases the risk of scald injury.
• Always supervise young children or others who are
incapacitated.
• If the water heater has been subjected to re, ood
or physical damage, turn o the manual gas shut-o
valve(s), and do not operate the
water heater again until it has been checked by
qualied personnel.
WARNING: Should overheating occur or the gas supply fail to shut o, turn o the
manual gas control valve to the water heater.
NOTICE: If the BATH control ls turned on, the temperature setting on the MAIN control
cannot be changed. The BATH control(s) will always have PRIORITY over the MAIN control.