16
PLEASE NOTE: EL22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND EL22-I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
English
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
HARDWIRING THE ELE CTRICAL
CONNECTIONS:
• Wiring should be carried out by a qualied
electrician in accordance with local codes.
• The water heater requires 120 VAC/60Hz
and should be properly grounded.
• DO NOT connect grounding wire to water
pipes, gas pipes, telephone cables,
lightning conductor circuits and to
grounding circuit of other equipment that
carry a ground-fault interrupter.
• An ON/OFF switch must be provided and
installed for the incoming 120VAC power.
• Wire the water heater exactly as shown
below. A wiring diagram is also found
inside
of the cover panel.
• A green screw is provided in the junction
box for grounding connection.
• Connect the live wire to black leg wire and
the neutral wire to the white neutral wire.
Electrical Connection
POWER CORD:
• The electric power supply requirement for
this water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin
power supply cord. Use only a power outlet
with a ground terminal.
• The installation of an electric leakage
breaker is recommended. (GFCI)
• Keep any excess of the power supply cord
on the outside of the water heater.
• If local codes require hardwiring, see
instructions for “Hardwiring the Electrical
Connections”.
WARNING :Field wiring connections and electri cal grounding must comply with local codes,
or in the absence of local codes, with the la test edition of the National Electrical Code,ANSI/
NFPA 70, or in Canada, Canadi an Electrical Code, CSA C22.1Part1.
WARNING: Shock hazard line voltage is
present. Before servicing the water heater, turn
o the electrical power to the water heater at
the main disconnect or circuit breaker. Failure to
do so could result in severe personal injury or
death.
CAUTION: Label all wires prior to
disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify correct operation after
servicing.
Electric Wiring Diagram