38
PLEASE NOTE: EL22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND EL22-I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
English
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Indoor unit mus t be ins talled with CAT 3
vent pipe in acc ordance with v ent
supplier/ Manufacturer in acc ordance with
loc al code. Owner must refer to vent
manufacturers instructions and
specications. Z-Flex information can be
found at www.novaex.com, please refer
to page 19 for additional links.
A. BACK INSTALLATION
1. Insert the vent pipe through the
installation holes in the wall with the terminal
sticking out.
2. Connect the elbow to the vent pipe and
water heater, moving straight backwards
until the expansion screws go into the holes
of the water heater. Screw the nuts tight
(pay attention to the direction of the elbow).
B. SIDE INS TALLATION:
1. Aim the holes in the water heater onto
the expansion screws, hang it up and screw
the nuts tightly.
2. Put the vent pipe through the holes in the
wall, and connect the elbow with the water
heater and vent pipe.
C. VERTICAL INSTALLATION
Please refer to local installation professional
or venting manufacturer:
The installation hole in the wall needs to
be sealed by re-retardant material or wall
thimble, making sure the water heater is tight
and will not come o.
Mounting the EL22-I Water Heater
Make sure the location of the water heater allows for easy access
and operation.
In case of dry wall or concrete wall use dry wall anchors or lag bolts.
The water heater requires 120VAC/ 60Hz. Have a receptacle with
ground terminal near the water heater. The length of the power
supply cord is 5 feet.
Drill the holes as per the sizes in the gure to the left, put 2
expansion screws into the top holes, and 2 rubber screws into the
bottom holes.
Hang up the water heater unit, tighten the expansion screws, and put
2 wood thread screws into the bottom holes.
CAUTION: Reinforcement of the wall is
required in case the wall is not strong enough
to hold the water heater.
EL22-I