Note
The replacement intervals depends on
the local water hardness. Areas with
hard water (e.g. III/IV) have a higher
replacement interval than areas with
soft water (e.g. I/II).
Indicator lamp at end of the run time
The "decalcification cartridge indicator
light" indicates when the decalcifica-
tion cartridge has to be replaced:
The indicator light flashes 2 hours
before the run time expires.
The indicator light flashes more
quickly 1 hour before the run time
expires.
The indicator light and the LED strip
on the device light up when the run
time of the decalcification cartridge
has expired. The floor covering sym-
bols on the handle do not light up.
The pump switches off automatically
(no water steam) to prevent damage
to the device.
Inserting the decalcification
cartridge
ATTENTION
Device damage
There is a risk of damage to the device
if the used decalcification cartridge is
re-used.
Work carefully in order to prevent mix-
ing up the cartridges.
Installation infor-
mation
When steaming for the first time after
removing and reinserting the decalcifi-
cation cartridge, the steam jet may be
weak or irregular, and individual drops
of water may be expelled. The device
requires a short running-in period
during which the decalcification car-
tridge fills with water. The steam vol-
ume that is expelled increases
constantly until the maximum steam
volume has been reached after ap-
prox. 30 seconds.
Note
Removing the water reservoir makes it
easier to remove and install the decal-
cification cartridge.
1. Press the OFF switch.
The device is switched off.
2. Remove the reservoir cover.
3. Remove the decalcification car-
tridge.
4. Insert the new decalcification car-
tridge and press it firmly into place.
5. Press the On switch.
The device is switched on.
6. Press and hold the RESET button
for 4 seconds.
The "replace decalcification car-
tridge" indicator light goes out and
the run time for the decalcification
cartridge starts again.