Loading ...
Loading ...
Loading ...
Page 16 INSTALLATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
ENGLISH
7.2 WIRED THERMOSTAT
Before installing the thermostat, unplug the power
cord from the power outlet.
First, connect the two thermostat wires to the terminal
block located at the rear on the right hand side of the
stove when facing it. Loosen the two middle screws
and insert the wires in the terminals. Tighten the two
screws. Open the thermostat and connect the wires
as per the manufacturer’s instructions.
Open the thermostat and connect the wires as per
the manufacturer’s instructions.
Connect one wire on “RH” and the other wire on “W”.
Red wire jumper can remain installed. For further in-
formation refer to the manufacturer’s instructions.
7.3 WIRELESS THERMOSTAT
If you are using a wireless thermostat or a hand
held thermostatic remote control, connect the two
thermostat wires to the terminal block located at the
rear on the right hand side of the stove while facing it.
If the receiver wires are equipped with quick-connect
terminals you can connect them directly to the stove’s
wiring harness.
To do so, open the right hand side decorative panels
and disconnect wires (B) and (C) attached to the rear
of the terminal block (A) and connect them to the re-
ceiver.
8. COMBUSTION AIR SUPPLY
NOTICE
For mobile home installation, it is mandatory to
connect the stove to an outside combustion air
source. Insulated pipe should never exceed 10
feet.
It is recommended to install an outside air inlet in or
near the room where the stove is installed. When
doing so, it is preferable to choose a wall which is
not exposed to dominant winds, depending on the
conditions surrounding your house.
Loading ...
Loading ...
Loading ...