PROBLEM
Pressure drops in the tank.
Air leaks at connections.
POSSIBLE CAUSE
POSSIBLE SOLUTIONS
Let the compressor build
pressure in the tank, to the
maximum pressure. If
possible brush soapy water
on air connections and look
carefully for air bubbles.
Tighten leaky connections.
If the problem persists,
contact the seller for further
advice.
The unloader valve leaks
when the compressor is idle.
Unloader valve seal
is defective.
Let the air in the air tank
flow out until all the
pressure is released. Then
remove the unloader valve
plug and clean the valve
seal. If necessary, replace
the seal and then reinstall
all components.
The compressor stopped
and does not start.
The thermal protector
turned on because the
motor is overheating.
Motor windings are
burned out.
Check that the main voltage
corresponds to the air
compressor specifications.
An extension cord that is
too thin or too long can
cause a voltage drop and
cause the motor to
overheat. Excessive use
(over 1 hour continuous
use) can cause the motor
to overheat. Allow the
motor to cool down.
Contact Customer Service
1-866-409-4581.
The motor does not start and
makes a humming noise
Capacitor is burned out.
Contact Customer Service
1-866-409-4581.
page 12
TROUBLESHOOTING