Installation and operation manual - Bistro woodburning cookstove
ENGLISH
8.1 Floor Protection
This stove is designed to prevent the floor from overheating. However, it must be placed on a
non-flammable surface to protect the floor from hot embers that may fall during loading.
Any type of tile will require a continuous non combustible sheet beneath to prevent the possibility
of embers falling through to the combustible floor if cracks or separation should occur in the
finished surface. Check local codes for approved alternatives. No protection is required if the
unit is installed on a non-combustible floor (ex: concrete).
FLOOR PROTECTION
Canada USA
G
4
8" (203 mm) N/A
H 8" (203 mm) N/A
I
18" (457 mm)
From door
opening
16" (406 mm)
From door
opening
J N/A 8" (203 mm)
K 42
7
8" (1089 mm) 39
7
8" (1013 mm)
N
5
N/A See note 5
S 48
3
8" (1229 mm) 38
3
8" (975 mm)
T 34 ¼" (870 mm) 27
1
8" (689 mm)
U 42
7
8" (1089 mm) 39
7
8" (1013 mm)
V 69
7
8" (1775 mm) 58
3
8" (1483 mm)
H
I
G
J
K
S
Figure 24: Floor protection
U
T
V
N
72"
183 cm
Ho
Ve
Figure 25: Clearances Figure 26: Clearances
4
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm).
5
Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm).