Installation and operation manual - Bistro woodburning cookstove
ENGLISH
APPLIANCE CLEARANCES (INSTALLATION
WITH SINGLE WALL PIPE CONNECTOR)
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
Canada USA Canada USA
A 15" (381 mm) 15" (381 mm) A 6" (152 mm) 6" (152 mm)
B 15" (381 mm) 15" (381 mm) B 15" (381 mm) 15" (381 mm)
C 7.5" (191 mm) 7.5" (191 mm) C 5" (127 mm) 5" (127 mm)
L 72" (183 cm) 72" (183 cm) L 72" (183 cm) 72" (183 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
3
FROM PIPE CONNECTOR WITH
SINGLE WALL PIPE CONNECTOR
DISTANCES
3
FROM PIPE CONNECTOR WITH
DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D 18" (457 mm) 18" (457 mm) D 9" (127 mm) 9" (127 mm)
E 25" (635 mm) 25" (635 mm) E 24.75" (318 mm) 24.75" (318 mm)
F 18" (457 mm) 18" (457 mm) F 15" (318 mm) 15" (318 mm)
3
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.