WARNING: PLEASE ENSURE THE MINIMUM CLEARANCE
DIMENSIONS INDICATED IN Fig.1 ARE MAINTAINED
WALL MOUNTING
The brackets for wall mounting the heater are supplied
fitted to the base of the heater. To wall mount the appliance,
first remove the brackets as follows:
Lay the heater on its back and remove the screw holding
the brackets in place. The brackets can then be removed
from the heater.
Select a suitable position on a wall, close to a suitable power
socket, making sure that the minimum clearances outlined
in Fig.1 are maintained.
The position of the top two wall mounting brackets can be
marked using the dimensions included in Fig.2 for reference.
Drill and fix the top two brackets to the wall using suitable
screw fixings.
Locate the heater on the top brackets and allow it to hang
in place. Fit the bottom bracket into the slot in the heater
and then mark and fix it to the wall.
Note: The heater should be hanging on the top brackets
with the bottom bracket in position before the bottom
bracket is fixed to the wall.
512
Min.
593
Min.
(X)
Min.
Shelf
PORTABLE USE
WARNING The heater must only be operated with the feet
securely fitted and in the upright position.
Never use the heater as a portable appliance without the
feet securely fitted using the screws provided.
To assemble the feet, lay the heater on its back and remove
the wall mounting brackets - see Fig.3, these can be
discarded or stored for future use.
Remove the two foot fixing screws, highlighted in Fig.3.
Assemble the feet by pressing them firmly into the
convector body as indicated in Fig.3, the foot should clip
into position.
Secure using the foot fixing screw,
Return the convector to the upright position,
The appliance is now ready for use.
(X)
ML2*** 358
ML3*** 478
WARNING: THIS APPLIANCE MUST BE EARTHED
DO NOT use an extension lead or multi-plug adaptor when
connecting this product to the mains. Connection through
these devices could lead to risk of overloading, overheating
and even fire at the extension lead or adaptor due to
inadequate connection quality.
This heater must be used on an AC (~) supply only and
the voltage marked on the heater must correspond to the
supply voltage. This heater is fitted with a rewirable plug
incorporating a 10/13 amp fuse. In the event of replacing
the fuse in the plug supplied, an equivalent 10/13 amp fuse
approved by ASTA to BS 1362 must be used. If any other type
of plug is used, a 15 amp fuse must be fitted in the plug, the
adaptor, or at the distribution board.
IMPORTANT: If the plug is not suitable for your socket, the 13
amp plug should be removed. Before wiring the appropriate
plug, please note that the wires in this mains lead are coloured
in accordance with the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
Connect the GREEN AND YELLOW wire to the terminal
marked ‘E’ or by the earth symbol , or coloured GREEN
or GREEN AND YELLOW. Connect the BROWN wire to the
terminal marked ‘L’ or coloured RED. Connect the BLUE wire
to the terminal marked ‘N’ or coloured BLACK.
The heater is designed for operation on an AC electricity
supply, and is suitable for use in domestic dwellings and
similar indoor locations.
The heater is supplied with feet and wall brackets to
provide the customer with the flexibility to choose between
portable or installed use. A rotary selector switch provides
the ability to select between Lo and High heat output,
each model contains a seven day electronic timer with an
integrated room sensing thermostat. It is supplied with a
cord and plug and is ready for use once the feet have been
fitted or the heater is mounted correctly.
Assembly and Positioning
The ML Convector can be used as a portable heater or can
be installed.
For portable use, always ensure that the heater is stood
on a firm, level base near to, but not directly underneath a
suitable mains supply socket.
Ensure that curtains and furniture are not positioned close
to the chosen position.
We recommend that the heater should be wall-mounted
in rooms where children may be left unattended, see
‘Important Safety Advice’.
If young children, the aged or infirm are likely to be left
in the vicinity of the heater, we advise that the adequate
precautions should be taken. We recommend that a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.
Electrical Connection
General
Fig. 2