Each joint in the assembly must be fastened with at least three screws.
The assembly must make allowance for expansion: elbows in assemblies allow for expansion; straight
assemblies should include an inspection wrap with one end unfastened, or a telescopic section.
Minimum upward slope towards the chimney: ¼ in/ft. (20 mm/m).
One end of the assembly must be securely fastened to the flue collar with 3 sheet metal screws and
the other end securely fastened to the chimney.
There must be provision for cleaning of the pipes, either through a clean out or by removal of the
pipe assembly. Removal of the assembly should not require that the stove be moved.
The male ends of the sections must be oriented towards the appliance so that falling dust and
condensation stay inside the pipe.
A flue pipe must never pass through a combustible floor or ceiling or through an attic, roof space,
closet or concealed space. Where passage through a wall or partition of combustible construction
is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning
Appliances and Equipment.
A straight up connector assembly needs either a telescopic length or an inspection wrap (pipe
coupler) to allow it to be assembled and disassembled without moving the stove.
A straight flue pipe assembly offers the least restriction to gas flow and results in a stronger draft.
Straight assemblies also need less maintenance because there are no corners to collect creosote.
The chimney connector must be clean and in good condition.
Mounting the stove adapter
Place the stove adapter in the flue collar. Use two self-
tapping screws in the holes provided to secure the stove
adapter so that it cannot be lifted or turned from the stove.
9.6.2 Installation of Double wall Chimney Connector
Important!
A double wall chimney connector can be installed only with the universal
connector supplied with the stove and a vented double wall stove adaptor.
To install a double wall connector on the appliance, the
universal connector supplied with the stove must be
installed as shown on the picture bellow..
A vortex double wall connector, with its vented stove
adapter (VOD0290), is recommended for this type of
installation. Consult www.drolet.ca for more details.
Other brands of double wall connectors are adequate
as long as they offer the option of a vented double wall
stove adapter.
Vented double wall
stove adaptor
Universal connector
PL36899