Installation and Operation Manual - Cape Town 1800
ENGLISH
8.1.1 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
IMPORTANT : Double wall pipe must be installed as
specified in section 9.6.2
Canada USA Canada USA
A 16" (406 mm) 16" (406 mm) A 16" (406 mm) 16" (406 mm)
B 18" (457 mm) 18" (457 mm) B 12" (304 mm) 12" (304 mm)
C 16" (406 mm) 16" (406 mm) C 12" (304 mm) 12" (304 mm)
L 72" (1828 mm) 72" (1828 mm) L 69" (1752 mm) 69" (1752 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
15
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE
IMPORTANT : Double wall pipe must be installed as
specified in section 9.6.2
Canada USA Canada USA
D 27,5" (699 mm) 27,5" (699 mm) D 27,5" (699 mm) 27,5" (699 mm)
E 19,5" (495 mm) 19,5" (495 mm) E 13,5" (342 mm) 13,5" (342 mm)
F 18" (457 mm) 18" (457 mm) F 14" (355 mm) 14" (355 mm)
Optional heat shield
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE USING
OPTIONAL HEAT SHIELD AC02791
16
Canada USA
A 16" (406 mm) 16" (406 mm)
B 8" (203 mm) 8" (203 mm)
C 12" (304 mm) 12" (304 mm)
L 69" (1752 mm) 69" (1752 mm)
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE USING
OPTIONAL HEAT SHIELD AC02791
16
Canada USA
D 27,5" (699 mm) 27,5" (699 mm)
E 11" (279 mm) 11" (279 mm)
F 14" (356 mm) 14" (356 mm)
15
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
16
See optional heat shield for double wall pipe accessory (AC02791) for its installation instruction.