Parameters c
an be checked in the following table below.
Parameter
code
Descriptions
0
Protection code or fault code
P.
1
Target f
requency
P.
2
Driving f
requency
P.
4
Outdoor EEV opening
P.5
Outdoor EEV t
arget o
pening
P.
6
Upper DC motor revolving s
peed
P.
8
AC Input v
oltage
P.
9
Current
P.10
Modular temperature
P.
11
Capacity n
eeded
P.
12
Modular f
ault
P.
20
Outdoor a
mbient temperature
P.
21
Outdoor c
oil t
emperature
P.
22
Outdoor defrost temperature
P.23
Suction t
emperature
P.
24
Discharge t
emperature
H.
1
DSH actual value
H.
2
DSH target value
H.3
Target pressure in cooling mode (Actual pressure= the displayed value/100)
H.
4
Target pressure in heating mode (Actual pressure= the displayed value/100)
9. FIELD SETTING
H.
5
Actual pressure (Actual pressure=the displayed value/100)
36K/60K
There are 3 buttons on the digital display board
S1
S2
S3
1) SWITCH button:
Indoor parameters and outdoor parameters can be selected in turn by pressing it.
“P.”/“H.”-outdoor unit parameter
2) INCREASE button:
Each time it is pressed, the number rises by 1, hold down it, the number will be rapidly increased;
3) DECREASE button
Each time it is pressed, the number lowers by 1, hold down it, the number will be rapidly decreased.
Select Increase
Decrease
Select Increase
Decrease
● ●
S5 S4