electrical information
It is necessary to hard wire this appliance.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National
Electrical Code in the United States.
5.0 electrical information
5.1 hard wiring connection
5.2 junction box installation
5.3 electronic wiring diagram
!
WARNING
Do not use this appliance if any part has been under water. Call a qualifi ed service technician immediately to
have the appliance inspected for damage to the electrical circuit.
Risk of electrical shock or explosion. Do not wire 110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes. In the
absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current National
Electric Code ANSI/NFPA NO. 70 in the United States.
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or
removed.
A. Remove the two screws that secure the junction box assembly to the outer shell on the left side of the
appliance and remove the junction box assembly.
B. Remove the one screw that secures the junction box to the
junction box plate and slide off the clip.
C. Route the supply wire through the 7/8” (22.2mm) hole of the
junction box plate with a box connector (not supplied).
D. Connect the 120 volt supply wire to the receptacle as per
the current CSA C22.1 Canadian Electrical Code in Canada
or the current ANSI/NFPA 70 National Electrical Code in the
United States.
E. Once the wiring is complete, re-install the junction box to the
junction box plate and re-secure the screw that was removed
in step B.
F. Re-install the junction box assembly by reversing step A
making sure all plugs are secure in the junction box.
B
1
B
2
A
note:
If the appliance is already installed inside the enclosure, you can access the junction box from inside the appli-