2
3. If an external electrical source is utilized, a statement that the appliance, when installed, must be
electrically grounded in accordance with local codes or, in the absence of local codes, with the National
Electrical Code. ANSI/NFPA 70.
4. A statement that:
(a) The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kpa).
(b) The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5kPa).
5. A statement of the maximum gas supply pressure in accordance with the inlet pressure rating of the gas
appliance pressure regulator supplied.
6. A description of proper vent installation, if applicable, and the specific type of gas vent to be used,
including a statement that the vent pipe must be mechanically fastened to the flue collar and
instructions for accomplishing this attachment.
IN THE COMMONWEALTH OF MASSACHUSETTS:
·This product must be installed by a licensed plumber or gas fitter.
·When using ball-type gas shut-off valves, they shall be the T-handle type.
·A flexible gas connector, when used, must not exceed 3 feet.
Be sure the installation of this product in a mobile home conforms with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280. If this standard does not apply, you must
follow the standard for Manufactured Home Installations, ANSI A225.1 and Manufactured Home
Installations, Sites and Communities, ANSI/NFPA 501A or with local codes. You can get a copy of the
Federal Standard by Writing: Office of Mobile Home Standards HUD Building 451 7th Street, S.W.
Washington, D.C. 24010.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage and frequency and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on the
rating plate.
We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician.
After installation, have the electrician show you where your main cooktop disconnect is located.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop
according to governing codes could result in a hazardous condition. If there are no codes, your cooktop
must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70—
Latest Edition. You can get a copy by writing: National Fire Protection Association Batterymarch Park Quincy,
MA 02269
In Canada, your cooktop must be wired and fused to meet the requirements of the Canadian Electrical
Code.